{{ $t('shop.all.spaetbestellservice.hinweis') }}
size | 12 |
Model series | MS |
installation position | arbitrary |
Construction set up | Pre-controlled membrane control valve |
Controller function |
Output pressure constant, With Return current behaviour, With relieving, With Pre-pressure compensation |
pressure display | with pressure gauge |
Operating pressure [bar] | 1.15 to 8 |
Pressure regulation range [bar] | 0.15 to 6 |
Max. pressure hysteresis [bar] | 0,04 |
Flow secondary venting [l/min] | <= 600 l/>in |
Normal nominal flow [l/min] | 12000 to 21000 |
Operating medium |
Compressed air to ISO 8573-1:2010 [7:4:4], Inert gases |
Corrosion resistant class KBK | 2 - moderate corrosion stress |
Bearing temperature [°C] | -10 to 60 |
Medium temperature [°C] | 10 to 50 |
ambient temperature [°C] | 10 to 50 |
Product weight [g] | 4.000 |
Fastening type |
pipe installation, With mounting bracket, Selectively: |
Pneumatic connection 1 | Connection plate |
Pneumatic connection 2 | Connection plate |
Cover material | PA |
Material information | RoHs compliant |
Cover down material | Aluminium wrought alloy |
Seals material | NBR |
Spring material | spring steel |
Housing material | Aluminium die casting |
Diaphragm material | NBR |
Valve tappet material |
NBR, Aluminium wrought alloy, High-alloyed stainless steels |
Operating voltage range DC [V] | 21.6 to 26.4 |
Max. electrical power consumption [W] | 3,6 |
Max. power input [A] | 0,15 |
Nominal operating voltage DC [V] | 24 |
residual ripple | 10 % |
Signal range analogue input | 0 - 10 V |
KC-mark | KC-EMV |
CE certificate (see declaration of conformity) | to EU EMC directive |
Protection category | IP65 |
{{ $t('shop.all.gewicht') }} | 4.000 g / Szt. |
{{ $t('shop.display.artikel.zollwarennummer') }} | 84811099 |
{{ $t('shop.all.hersteller') }} | Festo |
{{ $t('shop.all.spaetbestellservice.hinweis') }}
{{ $t('shop.all.wochenendversand.hinweis') }}
Wystąpił błąd; wczytaj stronę jeszcze raz i spróbuj ponownie.